Show simple item record

dc.contributor.advisorBulnes Bedón, Mario Santiago
dc.contributor.advisorFernández Dávila, Mónica Harm
dc.contributor.authorAntunez de Mayolo Maurer, Susana Ines Anaes_ES
dc.contributor.authorLeguizamo Galvis, Rosa Paolaes_ES
dc.date.accessioned2017-11-08T14:50:55Zes_ES
dc.date.available2017-11-08T14:50:55Zes_ES
dc.date.created2017es_ES
dc.date.issued2017-11-08es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12404/9676
dc.description.abstractLa presente investigación corresponde al proceso de creación, validación, estandarización y aplicación de un protocolo de evaluación de la triada succión-respiración- deglución en neonatos que permita comparar el desarrollo de la triada en los grupos evaluados, teniendo en cuenta 4 dimensiones: evaluación estructural y funcional, funciones estomatognáticas de succión, respiración y deglución y la relación entre la triada. La investigación es realizada con una población muestral de 400 neonatos de 24 a 72 horas de nacidos; divididos en dos grupos según la edad gestacional. El método utilizado es de tipo descriptivo-comparativo y sustantivo, no experimental – transversal. La validación se realizó a través del criterio de expertos, siendo procesados los resultados con el estadístico de Aiken. Así mismo, se realiza el análisis de ítem y el análisis de confiabilidad a través del Coeficiente de Alfa de Cronbach, se proporcionan las puntuaciones medias y desviación estándar y se procede a realizar el baremo de acuerdo con rango eniatipos por dimensiones. Luego se aplicó la prueba de ajuste normal de la muestra de Kolmogorov Smirnov, concluyendo la utilización de la estadística no paramétrica, usando el estadístico de U de Mann – Whitney para dar respuesta a las hipótesis planteadas, finalmente se realiza el correspondiente análisis cualitativo de los resultados obtenidos durante la aplicación del instrumento para describir las características de las funciones estomatognáticas de succión, respiración y deglución de los recién nacido. Se concluye que el protocolo si es un instrumento válido y confiable, que permite realizar comparaciones entre los grupos evaluados, de igual manera se concluye que sí existen diferencias en el desarrollo de las funciones estomatognáticas de succión, respiración y deglución de los recién nacidos a término y pretermino y según el tipo de parto.es_ES
dc.description.abstractThis study represents the process of creating a testing standard and validation of the breathing-suction-swallowing triad in newborn children to establish a fourway base line comprising the development of the triad of the studied groups, testing four dimensions: structural and functional, suction, breathing and swallowing – and the relations between the triad. The research was carried on four hundred newborn children between 24 and 72 hours of birth. This sample was divided in two groups according to their gestational age. The method used was descriptive-comparative-sustantive - non experimental - and transversal. Validation was done by expert peer review and the resulting data checked with Aiken Statistics. Also an item analysis was done and the trustworthiness by means of the Alpha coefficient of Cronbach. This study arrives at mean scores and the standard deviation. This study provides a scale with dimmensional enneatypes. The standard check-test of the Kolmogorow Smirnov sample was used ending the non parametric statistics analysis. Using the U of Mann- Whitney statistics to answer the arrived at hypothesis. Finally the qualitative analysis of the resulting data obtained after applying the Protocol to describe the characteristics of the stomatognathic functions: suction, breathing, swallowing on the newborn children. CONCLUSION: The Protocol is a valid and trustworthy instrument that enables comparison between the groups, showing that there are differences in the stomatognathic functions of newborn children with full and partial gestational term and type of birth.es_ES
dc.language.isospaes_ES
dc.publisherPontificia Universidad Católica del Perúes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/*
dc.subjectLactanciaes_ES
dc.subjectDegluciónes_ES
dc.subjectSucciónes_ES
dc.subjectNiños recién nacidos--Crecimientoes_ES
dc.subjectNiños recién nacidos--Alimentaciónes_ES
dc.titleDiseño, validación y aplicación del protocolo de evaluación de la triada succión – deglución – respiración en neonatos de 24 a 72 horas de nacidos de un hospital público de referencia nacionales_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
thesis.degree.nameMaestro en Fonoaudiología con mención en Motricidad Orofacial, Voz y Tartamudezes_ES
thesis.degree.levelMaestríaes_ES
thesis.degree.grantorPontificia Universidad Católica del Perú. Escuela de Posgradoes_ES
thesis.degree.disciplineFonoaudiología con mención en Motricidad Orofacial, Voz y Tartamudezes_ES
renati.advisor.dni08258705
renati.discipline916127es_ES
renati.levelhttps://purl.org/pe-repo/renati/level#maestroes_ES
renati.typehttp://purl.org/pe-repo/renati/type#tesises_ES
dc.publisher.countryPEes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.05.03es_ES


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess