Procesamiento de Señales e Imágenes Digitales.
Permanent URI for this collectionhttp://98.81.228.127/handle/20.500.12404/5040
Browse
2 results
Search Results
Item Soft tissue characterization using different quantitative ultrasound modalities(Pontificia Universidad Católica del Perú, 2019-10-24) Romero Gutierrez, Stefano Enrique; Castañeda Aphan, Benjamín; Lavarello Montero, Roberto JannielQuantitative ultrasound has been used in several modalities for different experiments such as simulated phantom, physical phantoms, ex vivo and in vivo tissues. The potential of the ultrasound techniques could be useful to complemented medical diagnosis. In this work, two quantitative ultrasound techniques are applied on in vivo experiments: crawling waves sonoelastography applied to bicep brachii and a regularized power law for backscattering and attenuation coefficient for ovary tumor. A crawling waves sonoelastography (CWS) method was applied using two mini-shakers making parallel contact (conventional setup) and normal contact with the surface in two phantoms (homogeneous and inhomogeneous) using the phase derivative algorithm to assess the performance of the normal excitation with well-know metrics such as error, coefficient of variation, signal-to noise ratio and contrast-to noise ratio. The results suggest that the normal excitation provides comparable stiffness estimation in homogeneous and inhomogeneous phantoms. For in vivo test, a bicep barchii from healthy volunteers were assess in two experiments: relaxed-contracted and with a range weight of load. The application of normal setup indicated that a measurement of the relative stiffness on bicep brachii can be realized. The results indicated that a using the incremental weight causes a increase on the stiffness of the bicep following a linear behavior. A regularized power law (RPL) method was implemented and testing with simulated phantoms using a combination of the possible variables of data block size and the regularized parameters of the three variables of the backscattering and attenuation coefficients. The results showed that is possible provide accurate and precise backscattering and attenuation coefficient in the same algorithm. Additionally, in vivo breast experiments was performed and compared with the literature obtaining comparable results. Finally, a tumor of patients with suspected ovarian cancer were assess. The results suggests that RPL method and in general provides reasonable depictions of the reflectivity and attenuation of interrogated media.Item Evaluation of shear wave speed measurements using crawling waves sonoelastography and single tracking location acoustic radiation force impulse imaging(Pontificia Universidad Católica del Perú, 2015-07-25) Ormachea Quispe, Juvenal; Castañeda Aphan, Benjamín; Parker, Kevin J.Many pathological conditions are closely related with an increase in tissue sti ness. For many years, experts performed manual palpation in order to measure elasticity changes, however, this method can only be applied on superficial areas of the human body and provides crude sti ness estimation. Elastography is a technique that attempts to characterize the elastic properties of tissue in order to provide additional and useful information for clinical diagnosis. For more than twenty years, di erent research groups have developed various elastography modalities with a strong interest for quantitative images during the last decade. Recently, comparative studies among di erent elastographic techniques have been performed in order to better characterize biomaterials, to cross-validate several shear wave elastographic modalities and to study the factors that influence their precision and accuracy. This comparison works may contribute to achieve standardization in quantitative elastography and their use in commercial equipment for their application in human patients. However, there is still a limited literature in the field of quantitative elastography modalities comparisons. This thesis focuses on the comparison between two elastographic techniques: crawling wave sonoelastography (CWS) and single tracking location-acoustic radiation force impulse (STL-ARFI). The comparison shows the estimation of the shear wave speed (SWS), lateral resolution, contrast and contrast-to-noise ratio (CNR) in homogeneous and inhomogeneous phantoms using both techniques. The SWS values obtained with both modalities are validated with mechanical measurements that are considered as ground truth. The SWS results for the three di erent homogeneous phantoms (10%, 13%, and 16% gelatin concentrations), show good agreement between CWS, STL-ARFI and mechanical measurements as a function of frequency. The maximum accuracy errors obtained with CWS were 2.52%, 1.63% and 2.26%. For STL-ARFI, the maximum errors were 6.22%, 5.63% and 4.08% for the 10%,13% and 16% gelatin phantom respectively. For lateral resolution, contrast and CNR estimated in the inhomogeneous phantoms, it can be seen that for vibration frequencies higher than 340 Hz, CWS presents better results than the obtained with STL-ARFI using distances between the push beams ( x) higher than 4 mm. However, using these vibration frequencies will not be feasible for in vivo tissues due to attenuation problems. It that sense, for lower vibration frequencies than 300 Hz and x among 3 mm and 6 mm, comparable lateral resolution, contrast and CNR was obtained. Finally, the results of this study contribute to the data currently available for comparing elastographic techniques. Moreover, the methodology implemented in this document may be helpful for future standardization for di erent elastographic modalities.