2. Maestría
Permanent URI for this communityhttp://98.81.228.127/handle/20.500.12404/2
Tesis de la Escuela de Posgrado
Browse
8 results
Search Results
Item Theoretical and experimental investigations of multiple contact points between a biologically inspired tactile sensor and various objects(Pontificia Universidad Católica del Perú, 2021-09-15) Fischer Calderón, Juan Sebastián; Alencastre Miranda, Jorge HernánThe somatosensory system of mammals includes sensory hairs (vibrissae) for tactile perception during near field exploration. Interacting with the environment, the tactile hair transfers mechanical stimuli to the hair follicle (follicle-sinus complex). The follicle-sinus complex transduces the singnals and transmits them to the central nervous system. Rats, e.g., are able to characterize objects with regard to their surface and geometric shape. Inspired by the biological paragon, the implementation of a vibrissa-like tactile sensor is an object of engineering research. According to the sensory organ, the function of a technical vibrissa is based on the recording of stimuli by the artificial hair shaft and their measurement at the support. This enables the detection of technically relevant information. In this context, the present work focuses on the task of object contour reconstruction. For that purpose, the support reactions are determined during scanning of an object. Previous investigations have been restricted on scanning objects with convex contours. This is due to the limitation of mechanical models to single-point contact scenarios. Goal of the present work is the consideration of multiple contact points between sensor shaft and object contour. The sensor shaft is modelled as a Euler-Bernoulli beam. The mathematical/theoretical description of the deformation of the beam during quasi-static scanning results in a multipoint boundary value problem with switching point. In order to simulate scanning sweeps along two different object types, the corresponding multipoint boundary value problems are solved by applying a shooting method incooperating a Runge Kutta Method of 4th order. The support reactions are calculated during scanning. It shows that multi-point contacts can be identified in the support reactions. The simulation is validated by experiments using selected examples.Item Contribution to artificial tactile sensors for object contour recognition using coupled technical vibrissae(Pontificia Universidad Católica del Perú, 2020-09-29) Eckhardt, Stefan; Zimmermann, Klaus; Alencastre Miranda, Jorge Hernán; Scharff, MoritzEinige Säugetiere verfügen zur taktilen Umgebungserkundung über spezielle Tasthaare, die sog. Vibrissen. Die Verwendung dieses komplexen Sinnesorgans ermöglicht es bspw. Rat-ten Abstände und Orientierungen von Objekten sowie deren Konturen und Oberflächenbe-schaffenheiten auf Basis weniger Berührungen durch ihre Vibrissen zu detektieren. Vibrissen kommen meist in Gruppen an verschiedensten Körperstellen (z.B. im Gesichtsfeld oder den Extremitäten) der Tiere vor. In der Literatur beschränken sich die meisten mechanischen Vibrissenmodelle auf die Betrachtung einer einzelnen Vibrisse, die zumeist als eingespann-ter Biegebalken modelliert wird. An dieser Stelle setzt die vorliegende Arbeit an und leistet einen Beitrag zur Untersuchung realitätsgetreuerer, elastisch gekoppelter Vibrissensysteme. Der Fokus liegt auf der Objektkonturabtastung und der theoretischen Erzeugung der Lager-reaktionen jeder einzelnen Vibrisse. Dabei werden das elastische Gewebe der Tiere, in das die Vibrissen eingebettet sind und die dadurch gegebene mechanische Beeinflussung der Vibris-sen untereinander berücksichtigt. Zunächst erfolgt die Modellierung einer einzelnen Vibrisse durch einen langen, schlanken Balken zylindrischer Form dessen Verformungen mithilfe der nicht-linearen Euler-Bernoulli Theorie beschrieben werden. Das Modell wird anschließend in verschiedenen Abstraktionsstufen zunächst um eine elastische Lagerung und anschließend um eine zweiten Vibrisse erweitert. Die Kopplung der Vibrissen wird durch verschiedene Federstrukturen realisiert. Für die Objektabtastung wird das Vibrissenmodell quasi-statisch und translatorisch an einer exemplarisch betrachteten, streng konvexen Objekt-Profilkontur vorbeigezogen. Während der Abtastung wird zwischen den Kontaktphasen des Spitzen- und Tangentialkontakts unterschieden. Darüber hinaus werden für den Fall der Objektabtastung mithilfe mehrerer Vibrissen verschiedene Szenarien abgeleitet, um zu berücksichtigen, welche und wie viele der Vibrissen sich gleichzeitig in Kontakt mit dem Objekt befinden. Basierend auf dieser Einteilung werden verschiedene Gleichungen zur Ermittlung der Fußpunktpositio-nen aller Vibrissen hergeleitet. Das mechanische Modell dient als Grundlage für die Durch-führung von Parameterstudien, in denen der Einfluss der Lager- bzw. Kopplungselastizität sowie des Objektabstandes auf die Lagerreaktionen der einzelnen Vibrissen untersucht wird. Dabei zeigt sich u. a., dass, im Gegensatz zum Objektabstand, eine Lagerelastizität in Ab-tastrichtung keinen Einfluss auf die Maximalwerte der Lagerreaktionen hat. Im Falle zweier gekoppelter Vibrissen können bestimmte Events, wie das Ablösen einer Vibrisse vom Objekt, in den Lagerreaktionen der jeweils anderen Vibrisse detektiert werden.Item Developing of a device for measuring the areal distribution of the forces in the contact zone of foot and underground for the use in leg prostheses(Pontificia Universidad Católica del Perú, 2020-09-18) Kubisch, Jörg; Fröhlich, Thomas; Elías Giordano, Dante ÁngelThe presented work demonstrates the process of designing a cheap, low cost three axis force sensor. Further it describes its integration in an array of multiple sensors to measure the distribution of forces acting on the sole of a prosthetic foot. The focus will be on easy manufacturing and common materials since the sensor will be integrated in a low cost prosthesis for lower limp amputees. Using the knowledge from bio mechanics and some basic assumptions for the later use, requirements for the project are derived. After a presentation of some state of the art sensor principles, suitable concepts are collected. Than, the concepts are compared using a comparison table to find the one the fits the requirements the best. A very compelling concept using barometers casted in silicone rubber is tested using a simple prototype to try out whether it is a good candidate or not. The tests show that the concept is capable of measuring forces but due to its disadvantageous susceptibility for temperature changes it is rejected for the further development process. The concepts are reevaluated and a new concept is chosen. Afterwards the design process is described. Beginning with the mechanical design explaining the working principle. The calculation of the dimensions is presented. After that a circuit to work with a capacitive measurement as well as a version for resitive measurement is developed and a layout for a prototype board using capacitive measurement is proposed. To prove the functionality, the capacitive system is built up as a prototype. To try the measurement behavior and to measure its repeatability a test stand is designed. It uses commercial available load cells to conduct a reference measurement. The output of the sensor is compared to the reference measurement. With various different test procedures the curves mapping the measured values to the force for normal and shear force measurement are determined. During the tests, different aspects of performance like creep behavior or hysteresis are investigated. Also the repeatability is measured various times under different loads to make reliable estimations of the precision of the measurement. Further on, a resistive force sensor which could be used instead of the capacitive sensing elements is tested regarding its curve and performance to have a comparison of the advantages and disadvantages of either designing the future sensor with resistive or capacitive sensing elements. With both concepts a repeatability of a few percent uncertainty can be achieved. Further on ways to improve future versions of the sensor are described based on the experiences made during the work with the prototype. Finally a possible way to integrate multiple sensors into a sensing array is proposed. The design as well as possible electrics to acquire the data are discussed. This way a solid basis for further developments of a sensing array measuring the force distribution is given.Item Determination of the signals recorded by carpal vibrissae of rats during locomotion and forelimb touch down(Pontificia Universidad Católica del Perú, 2020-09-04) Müller, Sebastian; Zimmermann, Klaus; Alencastre Miranda, Jorge Hernán; Scharff, MoritzVerschiedene Säugetiere, so auch Ratten, verfügen an ihren Pfoten über Tasthaare, die sog. karpalen Vibrissen. Untersuchungen der Fortbewegung von Ratten haben gezeigt, dass der Kontakt zwischen den karpalen Vibrissen und dem Untergrund Einfluss auf das Fortbewegungsverhalten der Tiere hat. Karpale Vibrissen bestehen aus einem Haarschaft und einem Follikel. Der Haarschaft ist lang, schlank, elastisch und im Follikel gelagert, in dem sich die Mechanorezeptoren befinden. Ausgehend von Vorarbeiten der Fachgebiete BiomechatronikundTechnischeMechanikderTechnischenUniversitätIlmenausowieder Section of Mechanical Engineering, Pontificial Catholic University of Peru, wurde ein mech- anisches Modell einer karpalen Vibrisse erstellt. Zielsetzung der vorliegenden Arbeit ist es, die imFollikelwirkendenKräfteundMomente währendder FortbewegungeinerRatte zu bestimmen. Aus den ermittelten Signalen sollen Rückschlüsse auf die Beschaffenheit des Kontaktes zwischen Haarschaft und Oberfläche gezogen werden. Hierzu wurde die in einer Vorarbeit ermittelte Bewegungsbahn einerRattenpfotemitdem indieserArbeit erstellten mechanischen Modell kombiniert. Die daraus entstandene invers dynamische Analyse wurde im Mehrkörpersimulationsprogramm ALASKA durchgeführt. Da nicht alle Eigenschaften und Parameter des biologischen Vorbilds bekannt sind, wurden z.B. der Reibkoeffizient, die Lagerungseigenschaften oder die Materialeigenschaften des Haarschaftes variiert. Als Ergebnis der durchgeführten Parameterstudien konnten verschiedene Einflüsse bestätigt werden. Hierbei zeigen sich u. a. Effekte wie eine Änderung der Signalstärke sowie Än- derungen in der Kontaktzeit.Item Diseño y construcción de un distractor ontogénico mandibular externo tridimensional de movimiento discreto(Pontificia Universidad Católica del Perú, 2017-11-04) Otiniano Chávez, Dany Martín; Barriga Gamarra, Eliseo BenjamínEn el cuerpo humano a veces se presentan alteraciones en el esqueleto tanto en el crecimiento como en el desarrollo del mismo en diversos grados, actualmente se practican técnicas que tiene por objetivo la corrección de los crecimientos anormales que se presentan en el esqueleto. El objetivo del presente trabajo es la corrección de los crecimientos anormales que se presentan en el maxilar inferior, la técnica a utilizar es la denominada distracción osteogénica, esta técnica ha demostrado que la tracción gradual de los tejidos vivos crea fuerzas que estimulan el crecimiento y la regeneración de los huesos. Se diseñó y construyó un dispositivo, el cual logrará de manera satisfactoria una tracción gradual sobre mandíbula inferior, ocasionando que esta modifique su geometría. El diseño del dispositivo utilizó una “Metodología del diseño”, ésta es una técnica reconocida, la cual nos garantiza que el dispositivo cumpla con todos los requerimientos y restricciones necesarias para lograr la distracción osteogénica. Los cálculos de las piezas del dispositivo denominado Distractor fueron verificados utilizando el Método de los Elementos finitos (CAE). También se presentan los planos del Distractor, los cuales sirvieron para la fabricación y ensamble del mismo, las piezas se fabricaron en talleres nacionales.Item Diseño mecánico de una prótesis activa transfemoral(Pontificia Universidad Católica del Perú, 2017-05-12) Medina Barrenechea, Samuel; Villota Cerna, Elizabeth RoxanaLas prótesis activas de miembro inferior buscan ejercer sobre el muñón de la persona amputada movimientos y reacciones similares a las que produce un miembro sano. Esto se logra por medio de sistemas que brindan potencia a las articulaciones, a diferencia de las prótesis pasivas. La finalidad de reproducir movimientos y reacciones similares a la de un miembro inferior es reducir el costo metabólico que puede demandar el emplear una prótesis pasiva y reducir las lesiones en otras partes del cuerpo producto de requerir mayor esfuerzo y movimientos anormales para suplir la función que brinda un miembro inferior sano. El objetivo de este trabajo es presentar el diseño mecánico de una prótesis activa transfemoral. El diseño fue concebido para que la prótesis pueda realizar rutinas de marcha en estado activo. Para rutinas como bipedestación y sedestación la prótesis se comporta de forma pasiva. El presente trabajo presenta un marco teórico de la marcha de la persona, las características de proyectos actuales de prótesis activas de miembro inferior, un método de obtención de reacciones en las articulaciones a partir de información obtenida de un análisis de marcha y la información de la persona modelo, la aplicación de la metodología de diseño empleada, el diseño de los sistemas de transmisión de potencia y de la estructura, la selección de componentes y el diseño preliminar del sistema de control. La prótesis diseñada se compone de cuatro partes, denominadas segmentos, y tres articulaciones, de las cuales dos de ellas son activas. Cabe resaltar que se emplearon elementos de almacenamiento de energía para reducir el tamaño de los actuadores y reutilizar la energía emitida por cada articulación.Item Mechanical bearings with tunable compliance after biological role model of blood sinus hairs(Pontificia Universidad Católica del Perú, 2016-06-20) Ingaroca Quispe, Jorge Luis; Helbig, Thomas; Alencastre Miranda, Jorge HernánIn follicle sinus complex of sinus hairs, two blood vessels seem to have a prominent function. Up to date, their biological role is unknown, however, hypothesis suggest that they are used as hydraulical bearing for the hair which is used to change the stiffness and compliance of the fixation depending on the application. Because of the size of the structures of interest experiments at the living object to clarify the biological role are not possible so far. Therefore, mechatronic approaches can help to investigate advantages and possibilities of a bearing with tunable compliance. Thus, in the current thesis, it is develop a mathematical modeling, multi-body simulation and a mechatronic demonstrator of a swinging rod in a bearing with tunable compliance. The tunable compliance of the system was inspired of Jack Spring principle of work, which change the compliance by decreasing the number of active coils.Item Modelado y optimización de una placa (implante) para sujeción de injerto en la columna vertebral por el método de los elementos finitos(Pontificia Universidad Católica del Perú, 2011-05-09) Álvarez Sánchez, Helard HenryEl objetivo del trabajo es analizar la placa (implante) a través de un modelo capaz de proporcionar valores de tensiones y desplazamientos bajo las diferentes condiciones de carga en distintos puntos de la placa que pueden son necesarios conocer. Esta información es de gran importancia, porque una cirugía persigue que la prótesis hueso del sistema este bajo un estado mecánico íntimo al hueso, promueve una estabilidad más grande y durabilidad de la placa y reduce el número de cirugías necesarias durante la vida del paciente.