Show simple item record

dc.contributor.advisorAcero Martínez, José Alberto
dc.contributor.authorCollantes Pacheco, Jose Carlos
dc.contributor.authorMorales Balcázar, Luis Antonio
dc.date.accessioned2023-03-22T18:41:20Z
dc.date.available2023-03-22T18:41:20Z
dc.date.created2023
dc.date.issued2023-03-22
dc.identifier.urihttp://hdl.handle.net/20.500.12404/24515
dc.description.abstractEl proyecto a desarrollar consiste en un edificio multifamiliar de muros de concreto armado de 6 niveles, ubicado en el Jr. Manco Segundo 2680, distrito de Lince, provincia de Lima, Perú. El primer piso albergará la recepción y estacionamiento, mientras que los pisos superiores albergarán 7 departamentos simples y 2 dúplex El territorio peruano se encuentra ubicado en el denominado “Cinturón del fuego del Pacifico”, lugar donde convergen y se originan procesos de subducción entre la placa oceánica de Nazca y la placa continental Sudamericana. Esta convergencia da lugar a la ocurrencia de eventos sísmicos, por lo que las ciudades de la costa peruana se encuentran en permanente exposición al peligro sísmico. Por este motivo, el análisis y diseño del edificio será realizado considerando las especificaciones establecidas en la norma E.030 de diseño sismorresistente, de tal forma que el edificio pueda presentar un correcto desempeño frente a un evento sísmico. Se realizará el predimensionamiento, la estructuración, y el diseño de los elementos estructurales que conforman la edificación, siguiendo la normativa y lineamientos establecidos en el Reglamento Nacional de Edificaciones (RNE). Para complementar estos resultados, se realizará el modelamiento y análisis del edificio con ayuda del software ETABS. Con los resultados obtenidos, se realizará el diseño, memoria de cálculo y planos de los elementos estructurales de la edificación, siguiendo la norma E.060 de diseño en concreto armado. Como tema de investigación, se realizará el análisis estático no lineal de la edificación diseñada, aplicando el procedimiento basado en el empuje incremental de cargas (Pushover), obteniendo así, el desempeño sísmico de la estructura frente a un sismo frecuente y un sismo muy raro.es_ES
dc.description.abstractThe project to be developed consists of a 6-story multi-family building with reinforced concrete walls, located at Jr. Manco Segundo 2680, Lince district, Lima province, Peru. The first floor will house the reception and parking, while the upper floors will house 7 single apartments and 2 duplexes. The Peruvian territory is located in the so-called "Pacific Ring of Fire", a place where subduction processes converge and originate between the Nazca oceanic plate and the South American continental plate. This convergence gives rise to the occurrence of seismic events, which is why the cities of the Peruvian coast are permanently exposed to seismic danger. For this reason, the analysis and design of the building will be carried out taking into account the specifications established in the E.030 standard for seismic resistant design, in such a way that the building can present a correct performance in the face of a seismic event. The pre-dimensioning, structuring, and design of the structural elements that make up the building will be carried out, following the regulations and guidelines established in the National Building Regulations (RNE). To complement these results, the modeling and analysis of the building will be carried out with the help of the ETABS software. With the results obtained, the design, calculation memory and plans of the structural elements of the building will be carried out, following the E.060 norm of reinforced concrete design. As a research topic, the nonlinear static analysis of the designed building will be carried out, applying the procedure based on the incremental thrust of loads (Pushover), thus obtaining the seismic performance of the structure against a frequent earthquake and a very rare earthquake.es_ES
dc.language.isospaes_ES
dc.publisherPontificia Universidad Católica del Perúes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/2.5/pe/*
dc.subjectEdificios--Diseño y construcciónes_ES
dc.subjectConstrucciones de concreto armado--Diseño y construcciónes_ES
dc.subjectAnálisis estructural (Ingeniería)es_ES
dc.titleDiseño estructural de un edificio multifamiliar de muros de concreto armado de 6 niveles en Lincees_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
thesis.degree.nameIngeniero Civiles_ES
thesis.degree.levelTítulo Profesionales_ES
thesis.degree.grantorPontificia Universidad Católica del Perú. Facultad de Ciencias e Ingenieríaes_ES
thesis.degree.disciplineIngeniería Civiles_ES
renati.advisor.dni29662895
renati.advisor.orcidhttps://orcid.org/0000-0003-4154-9510es_ES
renati.author.dni72307168
renati.author.dni72529651
renati.discipline732016es_ES
renati.jurorTinman Behar, Marcoses_ES
renati.jurorAcero Martinez, Jose Albertoes_ES
renati.jurorSilva Matos, Julio Leonides_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
dc.publisher.countryPEes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_ES


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess